Optical incremental linear encoder TONiC with scale tape from stainless steel RSLM
- Production:
- Renishaw plc (Graet Britain)
- Encoder TONiC with scale tape from stainless steel RSLM
The new RSLM stainless steel line provides measurement accuracy comparable to high-precision glass scales, and it is offered in the range of up to 5 m. The linear encoder system with the RSLM line provides a total error (including slopes and linearity) of less than ± 4 μm at 5 m - the best result in the industry! In a system with optical signal filtering that is easy to install and has a periodic error of ± 30 nm and a resolution of up to 1 nm, the RSLM line retains all the advantages of the encoder in 20 μm increments, while ensuring the accuracy of a system with a significantly smaller pitch.
Features and Benefits of the TONiC T1010 reading head and Ti-Interface
- Periodic error: ± 30 nm, which ensures the accuracy of operation inherent in encoders with a smaller pitch.
- Compact overall dimensions: 10.0 × 35.0 × 13.5 mm (H×D×W).
- Extremely high signal stability under conditions not acceptable for most open optical encoders.
- User selectable automatic gain adjustment (AGC) mode allows to maintain a constant analog signal amplitude of 1 Vpp.
- Ability to work at speeds up to 10 m/s and temperatures up to 70 ° C.
- New opportunity! Increase the stability of positioning due to the optical signal filtering system, characterized by low noise (jitter).
- Standard analog and digital output signals.
- Easy setup and diagnostics of the system thanks to LED indicators on the reading head and interface.
- The flexible cable between the reading head and the UL-compliant interface is up to 10 m long.
- Compliance with the requirements of the RoHS directive.
Ruler RSLM in stainless steel in 20 μm steps
The RSLM ruler in stainless steel with a pitch of 20 microns is excellent for those cases when it comes to moving within a significant length while maintaining high accuracy.
This robust ruler is offered with standard lengths up to 5 m.
The total error is less than ± 4 μm at 5 m.
- Coefficient of thermal expansion: 10.8 μm/m/ 0 С.
- Ribbon RSLM can be folded into a ring for convenient handling and storage, while in the straightened state it behaves the same as the scale ruler.
- Fixing with a special adhesive base or mechanical clamps.
- Optical zero mark IN-TRAC with automatic synchronization provides two-way repeatability of arrival to zero point at speeds of movement up to 12.5 m/s.
- Various zero-mark positions for IN-TRAC: in the middle of the scale (RSLM), at the end of the scale (RSLE), with distance codes for indexing short displacements (RSLD) or with equal intervals for customer selection (RSLC).
- Pair limit switches installed directly on the line provide an automatic feed of the signal that initiates the stop of the moved assembly.
Specifications
Built-in LED head position indicator |
Yes |
Measuring range, m: | — up to 5 |
Length of the optical scale RSLM, m: | —from 0,08 to 5 |
Resolution of digital output signal RS422, nm: | 1, 5, 10, 20, 50 , 100, 200, 500, 1000, 5000 |
Resolution of analog output signal: | — 1 Vpp |
Step of the scale, mkm: | 20 |
Max speed, m/s: | 10 |
Clearance between reading head and optical scale, mm: |
2,1 ± 0,15 |
Accuracy of the system at 20° C, μm: | ± 1,5 (in length up to 1 m) – ± 2,25 (in length up to 2 m) – ± 3 (in length up to 3 m) – ± 4 (in length up to 5 m) |
Scale option: | — base bracket and mounting clips - self-adhesive base |
Coefficient of thermal expansion, μm/m/°С: | 10,8 |
Supply voltage, V: | 5 ± 10 % |
Current consumption (without load), mA: | < 100 (analog system) — < 200 (digital system) |
Material of the optical scale RSLM: | — hardened martensitic stainless steel |
Cable: | — flexible, with double shielding, outer diameter 4,25 ± 0,25 mm, cable service life for bending more than 20 x 10 6 cycles with a bend radius of 20 mm, corresponds to UL standard |
Length of the cable, m: | 0.5, 1, 1.5, 3, 5, 10 (14-pin connector, for connection directly to the Si-interface) |
Dimensions of the reading head TONiC T1010 (height × length × width), mm: | 10,0 × 35,0 × 13,5 |
Mass, g: | reading head TONiC T1010 -10 - Si-interface - 100 |
Mass, g/m: | optical scale RSLM - 173 - cable - 26 |
Reference mark (zero): | optical, IN-TRAC, with automatic zero-signal synchronization |
Limit switches: | single, magnetic - paired, magnetic |
Temperature, °С: | — process - from 0 to + 70 - storage - from - 20 to + 70 |
Degree of protection: | - reading head T10101 – IP40 - Ti interface – IP20 |
Max humidity (without compensation, with temperature + 40 °C), %: |
95 |
Process acceleration, m/s 2: | 500 |
Impact (in non-operating state, 6 ms, half-sinusoidal impulse), m/s 2: |
1000 |
Vibration (in operation mode, at, at 55-2000 Hz), m/s2: | not more than 100 |
See also:
- Optical incremental linear encoder TONiC with steel scale tape with gold coating RGSZ
- Optical incremental linear encoder TONiC with a scale tape from Invar RELM
- Optical incremental linear encoder TONiC with scale RTLC in FASTRACK guides and with self-adhesive scale RTLC-S
Optical incremental linear sensor TONiC
Downloads:
Description and technical specifications
- Non-contact position encoders guide (EN) (pdf, 10`420 Кб)